Once two charging stations are installed in place, how can vehicle charging be coordinated with the site's existing power consumption? The answer lies in the controller and management software behind the charging stations.
In a factory parking lot in Taiwan, China, one Neuron III Lite (N3 Lite) connects to two ATP III AC charging stations in a "one-to-two" configuration. This case demonstrates the combined application of Alwayscontrol's smart charging kit at a specific site.
From monitoring on-site loads to coordinating charging output, and to viewing charging status and historical records, the N3 Lite × ATP III kit connects equipment, control, and daily management together.

The two ATP III charging stations on site are arranged along the building's exterior wall for vehicles to connect to when parked; one N3 Lite connects to both charging stations, forming a "one-to-two" configuration.
This corresponds to the equipment combination of Kit B: one N3 Lite plus two ATP III units. For two charging points, equipment layout and capacity management can be considered within the same solution.

N3 Lite: monitoring and control. It collects relevant power load information through CT current transformers, providing a basis for dynamic load management; the controller uses DIN rail mounting and can be configured according to power distribution conditions.
ATP III: vehicle charging terminal. It is responsible for providing AC charging to vehicles; the series supports Type 2 connectors, wall-mounted or pedestal installation, with an enclosure protection rating of IP65 and an impact resistance rating of IK10. The specific model selection needs to be based on site conditions.
Kit A consists of one N3 Lite with one ATP III; Kit B consists of one N3 Lite with two ATP III units. This case uses Kit B, demonstrating the coordinated combination of a controller and two charging terminals.

The kit adopts a PLC (Power Line Communication) solution, using power lines to transmit charging station control communication signals, which helps reduce the work of laying additional charging station control communication cables. Power supply, CT collection, and equipment installation still need to be implemented in accordance with on-site conditions and standards.
CT transformers provide load information, and N3 Lite coordinates charging output through dynamic load management (DLM) based on on-site power consumption conditions and configured capacity limits. When other loads increase, charging power is adjusted accordingly; when available capacity increases, the charging margin is then utilized appropriately.
For two charging stations, the key is to manage their combined charging load within the overall capacity range, allowing charging to adjust with changes in on-site power consumption and reducing the risk of tripping caused by excessive total load.

The accompanying software supports real-time monitoring, charging station device management, and records of historical charging counts and total charging volume. Users can learn about equipment and charging conditions through the management interface, providing reference for daily use and maintenance.
The solution also supports remote OTA firmware updates, providing support for subsequent equipment maintenance. The above is an introduction to the kit's functions; the actual scope of enabled functions in this case is subject to the on-site configuration.
This application at a factory parking lot in Taiwan, China brings one controller, two charging stations, and load management capabilities into a specific site. It also provides an equipment combination reference for projects with similar needs.
If you are planning one to two charging points, you are welcome to communicate with Alwayscontrol about on-site power supply capacity, load conditions, and charging needs to further understand the selection and application methods of N3 Lite × ATP III.